The heat that would have been required in each slot to keep the tank at least at its comfort floor, for any compressor schedule: the static schedule's counterpart of attr(result, "unmet_heat_kw") of add_tank_optimization(), which uses this same function. Per slot of dt hours, with the level S following get_tank_level() (it stops at 0, the inlet temperature), Smin = Tcap * SOCmin / 100, k = (1 - loss/100)^dt and S~[t] = k * S[t-1] + (cop[t] * power[t] + backup[t] - heat_demand[t]) * dt the level the balance asks for:

Usage

get_tank_unmet_heat(
  power,
  heat_demand,
  cop,
  init,
  Tcap,
  SOCmin,
  loss = 0,
  time_resolution = 60,
  backup = 0
)

Arguments

power

numeric vector, compressor electric power (kW), such as the result of add_tank_optimization()

heat_demand

numeric vector, heat demand (kW thermal)

cop

numeric vector, coefficient of performance (heat per electric kWh)

init

numeric, level before the first slot (in kWh, not %)

Tcap

numeric, tank capacity (kWh thermal, > 0), as in add_tank_optimization(): the heat between the inlet water temperature and the top of the tank

SOCmin

numeric, comfort floor (%, between 0 and 100)

loss

numeric, standing loss of the level (% per hour)

time_resolution

numeric, time resolution of the time-series (in minutes)

backup

numeric, backup heater power (kW electric = kW thermal): attr(result, "backup_kw") of add_tank_optimization(), or 0 without a backup heater

Value

numeric vector of the unmet heat (kW thermal), one value per slot, rounded to 2 decimals

Details

unmet[t] * dt = max(0, min(Smin, k * S[t-1]) - S~[t])

that is the heat the tank gives from below its comfort floor, plus the demand it cannot serve at all at the inlet temperature. It is positive while the level falls below the floor, and 0 while the level stays at or above it or rises back towards it; standing losses below the floor are not counted, and neither is a slot whose gap is within half a rounding step of the power (0.005 * max(cop, 1) * dt kWh).

Examples

# A 3 kWh tank with its floor at 1 kWh, emptied by 2 kW for 2 hours
get_tank_unmet_heat(
  power = c(0, 0, 0), heat_demand = c(2, 2, 0), cop = 3,
  init = 3, Tcap = 3, SOCmin = 100 / 3
)
#> [1] 0 2 0