  • Breaking: charging_power_min is now always a power in kW, in smart_charging(), smart_v2g() and schedule_sessions(). Up to 1.12.0 a value below 1 was a share of the nominal power, so charging_power_min = 0.5 meant 50% and now means 0.5 kW: callers passing a share must pass the kW value instead. The default of schedule_sessions() goes from 0.5 (50%) to 0. A value that is not a single number of at least 0 is an error.
  • One minimum applies to charging and to discharging: with charging_power_min = 4, method = "curtail" curtails down to 4 kW and no further, and smart_v2g() charges or discharges at 4 kW or more, or not at all. A session may still charge less than the minimum in its last charging slot, where it only needs that much to finish (the tail of its charge). smart_v2g() used to push a discharge inside (-min, 0) to the SoC floor’s limit, so a session the floor allowed only -2 kW discharged at -2 kW against a 4 kW minimum; it now does not discharge in that slot.
  • A session whose nominal Power is below charging_power_min (e.g. 3.7 kW against 4 kW) is not flexible, in both functions and whatever the method: it is never responsive, charges as uncontrolled (never curtailed, never discharged), and the setpoint carries its load as fixed instead of planning flexibility it cannot give.
  • Departure deadlines in the setpoint. smart_charging() and smart_v2g() merge the sessions of a profile into one flexible load, and the setpoint could postpone energy owed to a car that leaves early into the slots of the cars that stay longer, forcing the scheduler to catch up before each departure. The setpoint now keeps, at every slot, at least the energy_min share of the energy of the sessions that have already departed. A new internal helper, get_flex_envelope(), computes this and the existing nominal-power ceiling (LFmax) once for both functions.
  • smart_v2g() plans charge and discharge only while vehicles are connected: its setpoint is bounded by the nominal power of the connected responsive sessions (and load_capacity) in both directions, where it used to have no bound and could discharge with no vehicle plugged in. Its cumulative load never drops below the energy owed to the departed sessions minus what the connected ones can still discharge down to their SoC floor. When a grid capacity asks for more than the connected vehicles can give (an import cap of -20 kW with 15 kW plugged in, or a cap before the first arrival), the setpoint approaches it as far as their power allows, with a message, before falling back to relaxing the capacity to the original profile.
  • smart_v2g() reads the arrival State-of-Charge of each session from a new optional StateOfCharge column of sessions (a fraction, 0 <= StateOfCharge < 1, default 0.5 when the column is absent), and gains soc_min (last, default 0.2, 0 <= soc_min < 1), the SoC floor of every session. Both used to be fixed at 0.5 and 0.2 inside the scheduler. The battery capacity is Energy / (1 - StateOfCharge): the session’s energy takes it from its arrival SoC to full (twice the energy at 0.5, as before). With energy_max below 1 a session leaves below full, at StateOfCharge + energy_max * (1 - StateOfCharge). A session that arrives below its floor charges up to the floor first, as fast as it needs to, and can neither be curtailed nor discharge before it reaches it.

flextools 1.12.0

  • New get_tank_unmet_heat(): the unmet heat of any tank schedule (the heat that would have been required in each slot to keep the tank at least at its comfort floor), such as the static schedule’s. add_tank_optimization() computes its unmet_heat_kw attribute with it, so both share one definition.
  • add_tank_optimization() gains on_failure (last, default "flexible"): with "error", a window the solver fails on stops with an error naming its first datetime and the solver status, instead of running flexible with a message.

flextools 1.11.0

  • add_tank_optimization() gains a resistive backup heater and a soft comfort floor, so every window has a schedule. The new argument Pb (last, default NULL) is the backup heater’s rating in kW electric (= kW thermal, COP 1); NULL or 0 means none. The balance becomes S[t] = S[t-1] * (1 - loss/100)^dt + (cop * P + B - heat_demand) * dt with 0 <= B <= Pb (also where cop = 0). The level is measured above the inlet water temperature (SOC = 0, where the tank gives no more heat). When the compressor and the backup heater cannot hold SOCmin, the tank cools below it, down to the inlet temperature at most, and the unmet heat is the heat that would have been required to keep it at least at its floor (the heat it gives below the floor, plus the demand it cannot serve at the inlet temperature). The backup heater’s load enters the objective like the compressor’s, plus 2 * h per kW; going below the floor costs 20 * h / dt per kWh and slot (the end-of-window rule becomes soft at the same price), h being the window’s highest value of a kW of load in the objective (the highest absolute price for "cost", the largest derivative of the squared net flow for "grid", both weighted for a numeric objective). So the solver uses the compressor first, then the backup heater, and only then lets the tank cool below its floor. The soft floor only enters a window that has no schedule without it. The result gains the attributes backup_kw and unmet_heat_kw (one value per row, rounded to 2 decimals). Without a backup heater and in windows whose band holds, the results are unchanged.
  • add_tank_optimization() makes the grid capacities soft, as add_battery_optimization() does: a window with no schedule that holds the band within them is solved with the soft comfort floor and a penalised slack on each capacity (10 * h per kW, between the backup heater and the comfort floor), bounded by how far the site misses the capacity with the heat pump running flexible (import) or off (export). This replaces the relaxation of the capacities to the static schedule’s net flow and the fallback to flexible: every window now has a schedule, and the infeasible_windows attribute is gone. A missed capacity is reported with a message.
  • add_tank_optimization() also optimises the partial windows the run cuts at both ends: when the first slot is not a window start, the slots up to the first window_start_hour form a leading window (from SOCini, with the end-of-window rule at its last slot), and the slots after the last full window a trailing one, both limited to their first flex_window_hours like any window. Previously they ran flexible. With flex_window_hours = 24 * window_days every slot is now optimised.
  • The slots that still run flexible (past flex_window_hours, or in a window the solver failed on) behave like the tank too: the compressor stops as a thermostat would at SOCmax (the returned power there is flexible reduced to what keeps the level at the top), and below the floor the tank cools to the inlet temperature at most, with unmet heat. The level therefore never leaves [0, SOCmax], and the clamp into the band at each window start is gone: add_tank_optimization() no longer returns tank_clamp_kwh, and get_tank_level() loses its clamp argument.
  • get_tank_level() gains backup (default 0) and stops the level at the inlet temperature (0).
  • New article “Thermal optimization” on the tank model, the backup heater and the soft comfort floor, with a worked example in litres and degrees.

flextools 1.10.0

  • smart_v2g() gains energy_max (default 1, right after energy_min), the same cap smart_charging(energy_max = ) already has: every session charges at most this share of the energy it requires, net of discharge. Energy discharged still has to be charged back grossed up by discharge_eff, so with losses a session takes more than energy_max from the grid. The V2G setpoint optimisation now carries between energy_min and energy_max of the responsive sessions’ energy (previously exactly all of it): it targets energy_max, drops energy down to energy_min before relaxing the grid capacity, and when even the minimum does not fit relaxes the capacity only as far as the minimum-energy profile needs. Both ratios are validated like in smart_charging(). With the defaults (energy_min = energy_max = 1) the results are unchanged.

flextools 1.9.0

  • New add_tank_optimization(): a heat pump charging one thermal tank, optimised on the tank’s heat. It mirrors add_battery_optimization() (same opt_data conventions, windows from get_flex_windows(), "grid" and numeric weights on OSQP, "cost" on HiGHS) with the tank in place of the battery: the compressor’s electric power P heats the tank at the COP, the heat_demand column discharges it, and the level follows S[t] = S[t-1] * (1 - loss/100)^dt + (cop * P - heat_demand) * dt inside [SOCmin, SOCmax] of Tcap, with 0 <= P <= Pc, P = 0 where cop = 0, and every window ending at least as full as it started. The level carries across windows. opt_data gains heat_demand, cop and flexible (the static schedule, run outside every window and in a window with no feasible solution). It returns the compressor’s power, with the attributes infeasible_windows (the first datetime of each window that fell back) and tank_clamp_kwh (the heat the clamp into the band at each window start took out of the tank, signed, per row). SOCini = NULL means SOCmax; "capacity" and inputs out of range stop with an error naming the argument.
  • New get_tank_level(), the tank’s counterpart of get_storage_level(): the level in kWh at the start of each slot, applying the clamps it is given.

flextools 1.8.0

  • smart_charging() now splits every session whose connection crosses an optimization window boundary into one part per window before scheduling, with the energy shared by connection time. Previously such a session belonged to the window it started in, was never marked responsive there because its nominal charging ended past the window, and charged unmanaged at full power — with its raw demand added back into the setpoint, so the setpoint itself exceeded the grid capacity. Its flexibility, all of it on the far side of the boundary, was never used. Now each part is scheduled in the window it is connected in; the sessions schedule gains a Part column and a split session returns rows for each part under the same Session id (delivered energy is still sum(Energy) by Session). A part that could not fill one time slot at nominal power is folded into its longest neighbour instead of being emitted — evsim::get_demand() renders sub-slot charging as a whole slot at nominal power, which would inflate the optimizer’s view of it — so a session arriving shortly before a boundary moves whole into the next window. This changes results for any fleet with sessions spanning a window boundary; fleets without such sessions are unaffected (the package’s own golden test was re-captured for the two scenarios where the California fixture crosses the 06:00 boundary; the rest is byte-identical to 1.6.0).
  • The responsiveness test “charging ends inside the window” compared against the window’s last slot instead of its end, so a session whose charging ended exactly on the next boundary was excluded. Fixed.
  • The 95% arrival-time band is gone. Sessions whose connection times fell outside the profile’s mean +- 2 sd band in a window were “not considered”: never scheduled, charged unmanaged at full power, and not counted in the responsive share. The band existed to stop one late arrival from stretching the setpoint span and smearing the profile’s energy into slots where only that car was plugged in; the setpoint LP now bounds every slot by the nominal power of the sessions actually connected, which removes that failure mode at the source. Every session that charges inside a window is now considered. set_responsive() loses its opt_objective argument. This changes results for fleets with unusual arrivals.
  • Responsiveness is now looked up per session by its own Timecycle and Profile, instead of by the window’s most common time cycle. A Friday session carried over into Saturday’s window keeps Friday’s responsiveness; before, it was looked up under Saturday and, when that profile was not configured for Saturday, left unscheduled.
  • Fixed: with a single eligible session in a window, the responsive draw used sample(idx, 1), which samples from 1:idx rather than returning idx, so the wrong row could be marked responsive.
  • A met capacity no longer comes back one cent over it. Three roundings to 2 decimals stacked up so that a setpoint of 3.00 kW met exactly was reported as 3.01 (33 of 39 over-cap slots on the reference fleet): the flexibility requirement was rounded before the decision to act, the window demand was rebuilt from the session rows through evsim::get_demand(), which rounds each session’s slot power, and each profile column of the returned demand was rounded separately while callers sum the columns. Decisions are now taken on exact arithmetic against named tolerances (SCHEDULE_FLEX_TOL_KW = 0.001, the unchanged 0.1 kW / 0.025 kWh flexibility thresholds); schedule_sessions() returns the scheduled demand per slot (demand, summed from the exact per-slot powers) and smart_charging_window() uses it instead of rebuilding it; the session rows and the demand profile carry four decimals. The demand of non-responsive sessions still comes from evsim::get_demand().
  • Fixed a latent energy loss for straddling sessions: the window they spilled into overwrote the profile’s demand with the demand of its own sessions only, so the tail of a straddler vanished whenever another session of the same profile was scheduled that day. No session spills any more.

flextools 1.7.1

  • Fixed: with energy_min = 0, two fallback paths of the 1.7.0 energy range built a c(0, 0) ratio for a follow-up LP, which then stopped with “the maximum energy ratio must be higher than 0” — once when the capacity slice LP removed EV energy and could re-add none of it (the caps were already full of static load), and once when a window was infeasible for a reason energy cannot fix (production above the export capacity, load capacity). The first now returns the profile with the energy simply dropped; the second falls back to the original-profile capacity relaxation, as 1.6.0 did, after the minimum-energy relaxation has been tried where it exists. smart_charging() with energy_min = 0 no longer errors on such windows.

flextools 1.7.0

  • New energy_max argument in smart_charging(), smart_charging_window() and schedule_sessions(): the maximum share (between 0 and 1) of the energy each session requires that may be charged. Every session stops at energy_max * Energy, and the setpoint optimization targets exactly that share for the responsive sessions, so the setpoint and the scheduled demand agree — also with method = "none", where the setpoint is the result. Default 1. Must be at least energy_min.
  • energy_min now also bounds the setpoint optimization, not only the scheduler. The energy-conservation row of every demand LP (grid, cost, capacity, combined) becomes a range [energy_min, energy_max] * sum(LF) with a uniform reward on the optimized load that dominates the objective’s marginal gain from dropping energy, so the optimizer keeps as much energy as the grid capacity admits and drops the least that restores feasibility — never below energy_min. This changes results for callers passing energy_min < 1: against a capacity the fleet cannot fit under, the setpoint now holds the capacity and sheds energy, where before it conserved the energy and relaxed the capacity; and where the capacity does not bind, the energy is still delivered in full but a linear objective with a flat price (the cost objective is a tie among many equal-cost profiles) may land on a different profile than before. At the defaults (energy_min = 1, energy_max = 1) the setpoints are identical to 1.6.0 and the scheduled demand is unchanged up to the scheduler’s own 2-decimal rounding.
  • The infeasible-window fallback follows the same order: energy first, capacity second. When even energy_min * sum(LF) does not fit, the grid capacity is relaxed only as far as the minimum-energy profile needs (previously: as far as the full original profile needs), with its own warning message. The opt_objective = "none" branch of get_setpoints() likewise inflates the available capacity only as far as energy_min requires (previously: always enough for 100% of the energy).
  • smart_charging() and schedule_sessions() now validate the ratios and stop on energy_min > energy_max, energy_max = 0 or values outside [0, 1].
  • Not touched: smart_v2g() keeps its own setpoint path and has no energy_max; V2G is still under development.

flextools 1.6.0

  • The battery capacity objective now minimizes battery usage subject to the grid capacity, instead of minimizing the net grid flow with a capacity-sized slice of the battery. It keeps every constraint of the net power formulation and changes only the objective, from sum((L + B - G)^2) to sum(B^2). This changes results for opt_objective = "capacity": the battery now discharges onto the capacity line rather than below it, cycles only the overshoot volume, and recharges at the lowest power the window allows.

    The previous formulation reserved a slice of the battery sized to the overshoot and ran the net power objective on it, so the reserve was the only thing holding the optimizer back from flattening. Sizing that reserve against the usable SOC band in 1.5.0 - necessary, since a reserve too small could not clear the window at all - roughly doubled it, and the flattening it had been restraining became plainly visible: on a 4000 kW peak against a 3400 kW capacity the battery pulled the profile down to 2788 kW and cycled twice the energy the overshoot needed. Minimizing the battery directly removes the need for a reserve, so the nameplate no longer decides how hard the battery works - the capacity does, and two batteries that can both clear a window now return the same profile. Use "grid" to minimize the peak itself.

  • Fixed: the slack penalty was derived from the grid capacities rather than from the flows a solution can actually reach, so a capacity standing in for “unlimited” as a large finite number (rather than Inf, which is filtered out) produced a penalty large enough to wreck the solver’s conditioning - OSQP returned no solution and the battery was disabled for the whole window. It is now derived from max|L - G| + max(Bc, Bd), which bounds both objectives’ gradients and is tighter than the capacities in the common case.

  • Fixed: a battery window that fell back to the heuristic or to a disabled battery reported an empty solver status, because the message read result$info$status where solve_osqp() stores result$status_message.

flextools 1.5.0

  • A grid capacity the battery cannot fully meet is now concentrated rather than spread: the capacity is met exactly for as many slots as the battery’s energy covers, and missed on the remainder. Both spend the same energy and leave the same volume unserved, but the previous behaviour - a consequence of the slack penalty being linear in the volume missed, so the quadratic term chose the flattest of the equally-priced answers - left every affected slot marginally over its capacity. congestion_time counts slots, not kWh, so it stayed at 100% of the window for every battery size and only dropped once a battery covered the window outright. This changes results for the grid, capacity and combined objectives on windows where a capacity is out of reach. Runs the battery misses on power rather than on energy are left alone, since no arrangement of the energy meets the capacity there. The cost objective is unaffected: being linear, it already concentrated.
  • Fixed: the capacity objective reserved exactly the overshoot volume as the battery’s capacity, but the SOC band is a percentage of that reserve - so only a fraction of the volume was usable around SOCini, and the capacity went unmet however much battery the caller actually had. At the common SOCini = 50 a 4-hour forced export reached -63 kW against its -100 kW capacity, and doubling the battery changed nothing. The reserve is now sized against the usable SOC band.

flextools 1.4.0

  • Grid capacities are now soft constraints for the battery: a capacity the battery cannot physically reach is approached at full power instead of being dropped, which previously made the optimizer fall back to plain net-power flattening. The result is still guaranteed never to be worse than the profile without a battery, and slots that can meet their capacity stay strictly capped. Windows with no capacity to miss are solved exactly as before.
  • Fixed: a negative import_capacity or export_capacity — an obligation to flow the other way, e.g. a congestion contract requiring export — produced an inconsistent variable box (Col N has inconsistent bounds [0, -100]) on the cost and combined objectives. The solve failed and the battery was disabled for the whole window. Capacities are now imposed on the net flow.
  • Fixed: the capacity objective sized its curtailment from the one-sided imported/exported series rather than the net flow, which mis-sized the usable battery capacity whenever a capacity was negative.

flextools 1.3.0

flextools 1.2.0

  • Added V2G functions
  • Introduced timefully package
  • Function plot_net_power allows grid capacities in df

flextools 1.1.0

  • Added parallel processing
  • Multiple bug fix in smart_charging() function and introduction of “flex types”
  • Optimization functions accepting import_capacity and export_capacity instead of grid_capacity
  • Improvements in plot_smart_charging() function (e.g. by = "FlexType")
  • Added view_smart_charging_logs() function

flextools 1.0.0

  • First release with documentation.