Heat pump with a thermal tank: optimal compressor profile
Source:R/tank_optimization.R
add_tank_optimization.RdOptimises the electric power of a heat pump's compressor that charges one
thermal tank, which the heat demand discharges, with an optional resistive
backup heater next to it. It mirrors add_battery_optimization(): the same
opt_data conventions, objectives (except "capacity"), optimization
windows and solvers, with the tank in place of the battery. The compressor's
heat is cop * P, so there is no conversion efficiency: the COP is the
conversion. The backup heater turns B kW of electricity into B kW of heat.
Usage
add_tank_optimization(
opt_data,
opt_objective = "grid",
Tcap,
Pc,
SOCmin = 0,
SOCmax = 100,
SOCini = NULL,
window_days = 1,
window_start_hour = 0,
flex_window_hours = 24,
lambda = 0,
loss = 0,
Pb = NULL,
on_failure = c("flexible", "error")
)Arguments
- opt_data
tibble, optimization contextual data. The first column must be named
datetime(mandatory). Required columns:heat_demand: heat the tank must deliver (kW thermal, >= 0)cop: heat per electric kWh (>= 0); 0 means the compressor cannot serve the tank in that slotflexible: the static electric schedule of the heat pump (kW, >= 0), returned wherever the function does not optimise
Optional columns, as in
add_battery_optimization():static,production,import_capacity,export_capacity,price_imported,price_exported.- opt_objective
character or numeric.
"grid"(default),"cost", or a numeric weightwin[0, 1]wherew = 1is pure grid andw = 0is pure cost."grid"minimises the squared net grid flowstatic + P + B - production;"cost"minimises the energy cost of it."capacity"has no tank form and stops with an error.- Tcap
numeric, tank capacity (kWh thermal, > 0): the heat between the inlet water temperature (
SOC = 0, where the tank gives no more heat) and the top. For a mixed tank ofVlitres between the inlet temperatureT_inand its top temperatureT_max(degrees C), it isV * 4.186 / 3600 * (T_max - T_in), and a comfort floor atT_floorisSOCmin = 100 * (T_floor - T_in) / (T_max - T_in).- Pc
numeric, compressor cap (kW electric, > 0).
- SOCmin
numeric, minimum State-of-Charge (%), the comfort floor.
- SOCmax
numeric, maximum State-of-Charge (%).
- SOCini
numeric, State-of-Charge (%) at the start of the run, within
[SOCmin, SOCmax].NULL(default) meansSOCmax, unlike the battery: a tank starting at its floor has no reserve for its first window.- window_days
integer, optimization window length in days.
- window_start_hour
integer, start hour of each optimization window.
- flex_window_hours
numeric, flexibility window length (hours).
- lambda
numeric, ramping penalty weight on changes of
Pbetween consecutive slots.- loss
numeric, standing loss of the tank's level (% per hour, >= 0), as in
get_storage_losses().- Pb
numeric, rating of the resistive backup heater (kW electric, which is also its kW thermal, >= 0).
NULL(default) or 0 means no backup heater.- on_failure
character, what a window the solver fails on does:
"flexible"(default) runs theflexibleschedule there, as described in Soft grid capacities, with a message;"error"stops with an error naming the window's firstdatetimeand the solver status.
Value
numeric vector, the compressor's electric power (kW), one value per
opt_data row, rounded to 2 decimals: the optimised power in optimised
windows and flexible everywhere else, reduced where it would heat the
tank above SOCmax. Attributes:
backup_kw: numeric vector, one value per row, rounded to 2 decimals: the backup heater's power (kW electric = kW thermal); 0 outside optimised windows and everywhere without a backup heater.unmet_heat_kw: numeric vector, one value per row, rounded to 2 decimals: the unmet heat (kW thermal, not electricity): the heat that would have been required in that slot to keep the tank at least at its comfort floor (the heat it gave from below the floor, plus the demand it could not serve at the inlet temperature). 0 wherever the level stays at or above the floor, or rises back towards it. It is a report, not part of the balance.
The heat pump's electric load is the power plus attr(, "backup_kw").
Details
Per slot of dt hours, with S the level in kWh thermal above the inlet
water temperature (level 0, SOC = 0) and k = (1 - loss/100)^dt:
S[t] = k * S[t-1] + (cop[t] * P[t] + B[t] - heat_demand[t]) * dtTcap * SOCmin/100 <= S[t] <= Tcap * SOCmax/1000 <= P[t] <= Pc, andP[t] = 0wherecop[t] = 00 <= B[t] <= Pb, also wherecop[t] = 0every window ends at least as full as it started.
B (the backup heater) is a variable only with Pb > 0. The comfort floor
SOCmin is soft: when the compressor and the backup heater cannot hold
it, the tank keeps giving heat below it, cooling down to the inlet
temperature (level 0) at most, as a real tank would. The unmet heat is
the heat that would have been required to keep the tank at least at its
comfort floor: the heat it gives from below the floor, plus the demand it
cannot serve at all once it is at the inlet temperature. It is positive
while the level falls below the floor and 0 while it recovers, so it is a
missing energy, not a measure of how long or how far the tank stays below
its floor. Every window therefore has a schedule.
The run starts from Tcap * SOCini/100, and the level carries from one
window to the next. The windows are those of the other optimization
functions (one every window_days from window_start_hour), plus the
partial windows the run cuts at both ends: when the first slot is not a
window start, the slots up to the first window start form a leading
window, and the slots after the last full window a trailing window,
both optimised like any other window (the leading one from SOCini, both
with the end-of-window rule at their last slot). Only the first
flex_window_hours of every window are optimised, so with
flex_window_hours = 24 * window_days every slot is optimised. The slots
past flex_window_hours run the flexible schedule, without backup heater.
Compressor first, backup heater second, unmet heat last
The backup heater's electricity is part of the load the objective sees, like
the compressor's. To use it only after the compressor, and to cool the tank
below its floor only after both, the objective prices them from the
window's heat price h: the highest marginal value a kW of
electric load can take in the window's objective, divided by the lowest
positive COP when it is below 1, so that no kWh of compressor heat is worth
more than h:
"cost": the highest absolute import or export price of the window (EUR/kWh);"grid": the largest derivative of the squared net flow,2 * (max|static - production| + Pc + Pb)(kW);a weight
w:wtimes the grid value (scaled as the grid term of the objective is) plus1 - wtimes the cost value;with
lambda > 0, plus the largest derivative of the ramping penalty,4 * lambda * Pc.
The backup heater pays 2 * h per kW on top of its electricity, so it only
runs for heat the compressor cannot deliver (it never absorbs a PV surplus
the compressor could).
When a window has no schedule that holds the band within the grid
capacities, it is solved again with a soft floor: the level may go down to
0, and every kWh below SOCmin costs 20 * h / dt per slot, more than
any kWh of heat the compressor, the backup heater or a missed grid capacity
(below) can deliver. So the tank only cools below its floor when they
cannot hold it, and is brought back above it as soon as they can. The end
condition becomes soft at the same price, so a drained tank does not have
to be refilled by the end of the window. Without a backup heater and with a
band the compressor can hold, the problem, and so the result, is the one
without any of this.
Soft grid capacities
As for add_battery_optimization(), the grid capacities are soft: a window
that has no schedule holding the band within them is solved with the soft
comfort floor and with a penalised slack on each capacity. The slack is bounded by
how far the site already misses the capacity without optimisation (see
optimization_slack_ceiling()): for import, with the heat pump running
flexible; for export, with the heat pump off, since a full tank cannot
absorb a surplus. It costs 10 * h per kW (electric), between the backup
heater and the comfort floor: the solver uses the compressor and the backup
heater to their limits before it misses a capacity, and misses an import
capacity before it lets the tank cool below its floor. The heat pump off
with the tank cooling always fits these bounds, so every window has a
schedule.
A capacity left missed is reported with a message; compare the net flow
static + P + attr(, "backup_kw") - production with the capacities to find
where.
The slots that run flexible (past flex_window_hours, or in a window the
solver failed on, reported with a message, unless on_failure = "error"
stops the run there instead) keep the tank below its top: the
compressor stops as a thermostat would, its power there being flexible
reduced to what keeps the level at SOCmax. Below the floor they cool the
tank down to the inlet temperature at most, with unmet heat as above. So the
level stays between 0 and SOCmax everywhere, and get_tank_level()
reproduces it.
Inputs out of range stop with an error naming the argument; nothing is clamped into range, and no zero profile is returned in their place.
Examples
library(dplyr)
opt_data <- tibble(
datetime = as.POSIXct("2024-01-01", tz = "UTC") + 3600 * 0:23,
production = 0,
heat_demand = c(rep(1, 17), rep(6, 3), rep(1, 4)),
cop = 3,
flexible = 1 / 3,
price_imported = ifelse(0:23 < 6, 0.1, 0.3),
price_exported = 0
)
P <- add_tank_optimization(
opt_data, opt_objective = "cost", Tcap = 3, Pc = 1, Pb = 2
)
attr(P, "backup_kw")
#> [1] 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 2 2 0 0 0 0
attr(P, "unmet_heat_kw")
#> [1] 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
get_tank_level(
P, opt_data$heat_demand, opt_data$cop, init = 3,
backup = attr(P, "backup_kw")
)
#> [1] 3.00 2.00 1.00 3.00 2.99 3.01 3.00 2.00 1.00 0.00 -0.01 0.01
#> [13] 0.00 -0.01 0.01 0.00 1.01 3.01 2.01 1.01 0.01 0.00 -0.01 1.00