Set setpoints for smart charging
Usage
smart_charging_window(
sessions_window,
profiles_demand,
setpoints,
method,
power_th = 0,
charging_power_min = 0,
energy_min = 1,
energy_max = 1,
include_log = FALSE
)Arguments
- sessions_window
tibble, sessions corresponding to a single windows
- profiles_demand
tibble, user profiles power demand
- setpoints
tibble, user profiles power setpoints
- method
character, scheduling method being
"none","postpone","curtail"or"interrupt". Ifnone, the scheduling part is skipped and the sessions returned in the results will be identical to the original parameter.- power_th
numeric, power threshold (between 0 and 1) accepted from setpoint. For example, with
power_th = 0.1andsetpoint = 100for a certain time slot, then sessions' demand can reach a value of110without needing to schedule sessions.- charging_power_min
numeric, minimum charging power in kW. See
smart_charging().- energy_min
numeric, minimum allowed ratio (between 0 and 1) of required energy.
- energy_max
numeric, maximum allowed ratio (between 0 and 1) of required energy.
- include_log
logical, whether to output the algorithm messages for every user profile and time-slot